Energy-absorbing chambers ECC 800.625

Utility wastewater and stormwater energy-absorbing chamber

Outlet: DN/OD 160, 200, 250 mm; Inlet: DN/OD 110-200 mm
Energy-absorbing chambers ECC 800.625
Energy-absorbing chambers ECC 800.625
Energy-absorbing chambers ECC 800.625
Energy-absorbing chambers ECC 800.625


Energy-absorbing chambers DN 800 for utility wastewater and stormwater systems. Made from polyethylene (PE) material with D400 class self leveling or stationary type cover.

  • Connections:
    • Inlet DN/OD 110 .. 200 [mm]
    • Outlet DN/OD 160 .. 250 [mm]
  • Cover: D400 class (40t), RAL GZ-692
  • Access diameter 625 [mm]
  • Advantages

    No stagnant water in the chamber

    Resistant to aggressive environment, no corrosion

    Long service life (>50 years)

    Flexibile for movements in soil (no cracking of the manhole)

    Water-tightness > 0.5 bar, watertight materials

    The diameter of access hole allows convenient and quick maintenance of sewerage networks

  • Recommended application

    Intended for utility sewerage and rainwater pressure systems:

    • SDR17, PE80 class EN 12201-2+A1 pipes with nominal pressure class PN8 [bar];
    • SDR17, PE100 class EN 12201-2+A1 pipes with nominal pressure class PN10 [bar];
    • SDR17, PE100-RC class EN 12201-2+A1, PAS 1075 pipe types- 1, 2, 3 with nominal pressure class PN10 bar.

    Chamber installation according to: EN 1610, CEN/TR 1046

    Construction work related to chamber cover and upper part of chamber shall be performed in accordance with road or territory manager’s issued technical regulations and sewer system operator (water management service provider’s) requirements.

  • Chamber components
    Energy-absorbing chambers ECC 800.625

     

    1. OUT 0° DN 160 - IN R/L° DN 110
    2. OUT 0° DN 200 -  IN R/L° DN 125, 140, 160
    3. OUT 0° DN 250 -  IN R/L° DN 180, 200

    Note: On demand it is possible to manufacture inlet “IN(R/L)°” with flange connection

     

    1  to be used in cases of paving stone, gravel or green space.

    2  to be used in asphalt concrete pavement.

  • Technical information
    Installation depth:
    • Minimum instalation depth: 1.25 [m]
    • Maximum installation depth is up to 5.0 [m], if the ground water level is 2.0 [m] from the surface. If the ground water level is 0.0 [m] from the surface, the maximum installation depth is 4.0 [m], according to the requirements of EN 13598-2 standard
    Chamber cover:
    • Stationary type cast iron frame and cover, DN 600/746 [mm], installation class D400 (40t) corresponds to the requirements of EN 124-2 and RAL GZ-692 standard
    • Self-leveling type cast iron frame and cover, DN 700 [mm], installation class D400 (40t) corresponds to the requirements of EN 124-2 and RAL GZ-692 standard
    • Polymer ring adapter for self-leveling cover DN 710/870 [mm], durability tests are carried out corresponding to the requirements of EN 124 standard.
    • Polymer height adjustment ring DN 700/875 [mm], durability tests are carried out corresponding to the requirements of EN 124 standard.
    • Polymer support ring DN 680/1050 [mm], durability tests are carried out corresponding to the requirements of EN 124 standard.
    • Reinforced concrete height adjustmet ring, DN 665/1000 [mm], corresponds to the requirements of EN 206, EN 1917 and EN 1917/AC standard
    • Reinforced concrete support ring, DN 665/1060 [mm], corresponds to the requirements of EN 206, EN 1917 and EN 1917/AC standard
    Chamber shaft and base:
    • Polyethylene (PE) eccentric cone, DN 800/625, h=750/1000/1250/1500 [mm], corresponds to the requirements of EN 14802
    • Polyethylene (PE) chamber shaft, DN 800, h=500/1000 [mm], corresponds to the requirements of EN 14802
    • Polyethylene (PE) chamber base, DN 800, h=650/800 [mm], corresponds to the requirements of EN 13598-2, EN 476
    • To ensure the water-tightness of the chamber, the connecting elements are connected with rubber sealing rings DN 800 [mm] corresponding to the requirements of EN 681-1 and EN 1277 standards. The chamber must ensure the maximum pressure of 0.5 [bar].

    According to the requirements of EN 681-1 and EN 1277 standards, rubber sealing rings of chambers have to ensure water-tightness of connections at water pressure of 0.5 [bar]

  • Drawings

    Standard Drawing ECC DN800.625.D400.S PDF

    Energy absorbing chamber DN800 with D400 class stationary type cover

    Download
    Standard Drawing ECC DN800.625.D400.S PDF

    Standard Drawing ECC DN800.625.D400.SL PDF

    Energy absorbing chamber DN800 with D400 class self-leveling type cover

    Download
    Standard Drawing ECC DN800.625.D400.SL PDF

    Standard Drawing ECC DN800.625 DWG

    DWG file format

    Download
    Standard Drawing ECC DN800.625 DWG

Energy-absorbing chambers ECC 800.625

Utility wastewater and stormwater energy-absorbing chamber

Outlet: DN/OD 160, 200, 250 mm; Inlet: DN/OD 110-200 mm
Downloads

Standard Drawing ECC DN800.625.D400.S PDF

Energy absorbing chamber DN800 with D400 class stationary type cover

Download
Standard Drawing ECC DN800.625.D400.S PDF

Standard Drawing ECC DN800.625.D400.SL PDF

Energy absorbing chamber DN800 with D400 class self-leveling type cover

Download
Standard Drawing ECC DN800.625.D400.SL PDF

Standard Drawing ECC DN800.625 DWG

DWG file format

Download
Standard Drawing ECC DN800.625 DWG

Calculators

Calculations for energy-absorbing chambers

How to select energy-absorbing chambers connection sizes and determine the throughput.

Order information

  Product Code
  Chamber covers
Self-leveling round cast iron frame and cover, DN 700 [mm] 820215700SL7300007
Stationary type round cast iron frame and cover, DN 600/746 [mm] 820215601ST7300038
  Odour filter selection
Sewer air odour filter, DN 600 820230000000000000
  Shell ring adapter
Polymer shell ring adapter for self-leveling cover 822250836F80000000
  Polymer components
Polymer height adjustment ring, DN 700/875 [mm], h=15 [mm] 822072834340000000
Polymer height adjustment ring, DN 700/875 [mm], h=30 [mm] 822072834370000000
Polymer height adjustment ring, DN 700/875 [mm], h=50 [mm] 822072834N30000000
Polymer support ring, DN 665/1060 [mm], h=160 [mm] 822091832F70000000
  Concrete components (alternative solution)
Reinforced concrete support ring, DN 665/1060 [mm], h=160 [mm] 821072666850000000
Reinforced concrete height adjustment ring, DN 665/1000 [mm], h=60 [mm] 821073T09840000000
  Cone selection
Polyethylene ring type cone, DN800/625, h=750 [mm] on request
Polyethylene ring type cone, DN800/625, h=1000 [mm] on request
Polyethylene ring type cone, DN800/625, h=1250 [mm] on request
Polyethylene ring type cone, DN800/625, h=1500 [mm] on request
  Shaft selection
Polyethylene ring type shaft, h=500 [mm] 816024000400000134
Polyethylene ring type shaft, h=1000 [mm] 816024000460000134
  Sealing ring
Sealing ring, DN 800 [mm] 816026800000000034
  Chamber base selection
PE Spherical energy-absorbing chamber base DN 800 [mm], h=800 [mm] 816054000920000134
PE Spherical energy-absorbing chamber base DN 800 [mm], h=625 [mm] on request

Product pictures are provided for informative purposes only.
Proportions and colours of the original production may differ from the pictures.

Hello!

We use cookies to help improve your experience of our website. With your consent, statistical and analytical cookies may also be used on this website. If you agree to the use of these additional cookies, please mark your choice: